Abstract

<jats:p>Point-of-care Hepatitis C Virus (HCV) RNA assays reduce diagnostic turnaround time but depend on benchtop instrumentation and continuous electricity, limiting their deployment in the harm reduction and community settings where confirmatory testing is most needed, as people who use drugs (PWUD) carry a disproportionate share of the HCV burden in the United States. This is a systemic problem in diagnostic development, where decision-making and design requirements overlook point-of-use stakeholders. Closing the gap requires integrating real-world constraints throughout design rather than validating against user needs once a product already exists. Here, we apply a human-centered design (HCD) approach to inform rigorous, stakeholder-derived design requirements, implementation considerations, and early value proposition for a novel point-of-need HCV RNA test intended for deployment in harm reduction and community settings in Indiana. To determine design specifications grounded in real-world context, our objectives were (1) identifying and characterizing context-specific experiences and barriers to HCV testing among higher-risk populations; (2) assessing the perceived benefits and acceptability of the proposed test within real-world settings across direct and indirect user groups; and (3) translating the user needs and contextual constraints into design requirements and implementation considerations that support the test's clinical, operational, and user-centered value. We conducted 18 semi-structured interviews with frontline staff and HCV testing/treatment pipeline experts (n=11) and people who get tested (n=7) across harm reduction organizations, syringe service programs, and community testing settings, analyzed using Rapid Qualitative Analysis guided by the PARRQA framework. Stakeholders responded positively to a single-encounter point-of-need RNA test, and implementation considerations, including funding restrictions, staffing structures, and diverse deployment settings, directly shaped design requirements spanning turnaround time, sample type and volume, portability, result output, target operator, and ease of use. Benchmarking these stakeholder-derived specifications against the FIND Dx HCV target product profile (TPP) showed that stakeholder input confirmed, modified, or extended several TPP criteria and introduced requirements the TPP does not address. Together, these objectives constitute an upstream, evidence-driven design process that translates contextual and stakeholder knowledge into actionable engineering requirements, highlighting the need for diverse stakeholder engagement at all stages of the design process for closing the translation gap between laboratory-validated diagnostic tools and effective point-of-need deployment.</jats:p>

Show More

Keywords

design requirements settings deployment diagnostic

Related Articles


Deprecated: Function curl_close() is deprecated since 8.5, as it has no effect since PHP 8.0 in /home/u483256323/domains/poorvam.com/public_html/subdomains/pore/includes/api.php on line 76
PORE

About

Connect